HP ProLiant BL260c Generation 5 Server Blade Installation Instructions

Interconnect bay numbering and device
mapping
HP BladeSystem c7000 Enclosure
HP BladeSystem c3000 Enclosure
To support network connections for specific signals, install an
interconnect module in the bay corresponding to the embedded NIC
or mezzanine signals.
Server blade
signal
c7000
interconnect
bay
c3000
interconnect
bay
Interconnect bay
labels
NIC 1
(Embedded)
1 1
NIC 2
(Embedded)
2 1
Mezzanine 5 and 6 3 and 4
7 and 8 3 and 4
The server blade does not provide mezzanine signals for
interconnect bays 3 and 4 (c7000 enclosure) or for interconnect
bay 2 (c3000 enclosure).
For detailed port mapping information, see the HP BladeSystem
enclosure installation poster or the HP BladeSystem enclosure setup
and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure must
be configured with network interconnect devices to manage signals
between the server blades and the external network.
Two types of interconnect modules are available for HP BladeSystem
c-Class enclosures: Pass-thru modules and switch modules. For more
information about interconnect module options, see the HP website
(http://www.hp.com/go/bladesystem/interconnects
).
Installing a server blade
CAUTION: To prevent improper cooling and thermal
damage, do not operate the server blade or the enclosure
unless all hard drive and device bays are populated with
either a component or a blank.
1. Remove the device bay blank.
2. Remove the enclosure connector cover.