ProLiant BL e-Class C-GbE Interconnect Switch Command Line Interface Reference Guide
Configuring the Switch Modules using the Command Line Interface
Setting Date and Time Parameters Manually
IMPORTANT: If the system clock is set and power is lost to the interconnect switch, manual time
settings are reset to factory defaults when the interconnect switch is powered on. If this occurs,
manually reset the date and time. If SNTP is configured, losing power has no effect, so no manual
resetting of time is required.
The factory default for SNTP is set to disabled. This allows you to manually set the date and
time on the interconnect switch if desired. Use the time and date conventions in the following
table when configuring the date, time, local time zone, and local daylight saving time
parameters:
Table 2-2: Time and Date Conventions
Parameter Format
Time Type the time in hh:mm:ss format where
• hh—Two-digit hour
• mm—Two-digit minute
• ss—Two-digit second
For example, you would type 08:05:30 for five minutes and thirty seconds
after 8 AM in the morning.
Date Type a date in ddmthyyyy format where
• dd—Two-digit day of the month (01-31)
• mth—First three characters of the name of the month: jan, feb, mar, apr,
may, jun, jul, aug, sep, oct, nov, dec
• yyyy—Four-digit year
For example, you would type 05jun2002 for June 5, 2002.
Day of the Week Type the first three letters of the weekday: sun, mon, tue, wed, thu, fri, sat.
IMPORTANT: SNTP must be set to disabled to manually set the time.
Use the following command to manually set the time, date, time zone, and daylight saving
time parameters:
HP ProLiant BL e-Class C-GbE Interconnect Switch Command Line Interface Reference Guide 2-39