HP VPN Firewall Module Series - HP SECBLADEIII-CMW520-R3819P05 Release Notes

4
Condition: This symptom occurs if the Layer-3 subinterface or Layer-3 aggregate
subinterface are created before the two cards enter synchronization state.
Workaround: Configure the two cards to enter synchronization state, and then create
the Layer-3 subinterface or Layer-3 aggregate subinterface.
HSD110063
Symptom: When configuration synchronization is enabled between the active and
standby SecBlade cards, new physical interface type configuration on the active card
cannot be synchronized to the standby card.
Condition: This symptom can be seen when configuration synchronization is enabled
between the active and standby SecBlade cards.
Workaround: Manually modify the interface type configuration on the standby card.
HSD100621
Symptom: After the attack defense settings configured at the CLI are removed from
the Web interface and then the SecBlade card is rebooted, the attack defense
settings still take effect.
Condition: This symptom can be seen after the attack defense settings configured at
the CLI are removed from the Web interface and then the SecBlade card is rebooted.
Workaround: Remove the attack defense settings at the CLI.
HSD113033
Symptom: The SecBlade card might reboot when a display command with a regular
expression (for example, display current-configuration | include .*.*.*/.) is executed to
display a configuration file that exceeds 100 KB.
Condition: This symptom occurs if a display command with a regular expression (for
example, display current-configuration | include .*.*.*/.) is executed to display a
configuration file that exceeds 100 KB.
Workaround: When the configuration file is larger than 100 KB, do not use any regular
expression, or use a regular expression that does not include "*" or includes few "*".
List of resolved problems
Resolved problems in R3819P05
201403140300
Symptom: The SecBlade card unexpectedly reboots.
Condition: This symptom can be seen when IPsec requires the CPU to generate a
random number during SA negotiation.
Resolved problems in R3819P01
201401140211
Symptom: The SecBlade card fails to start up.
Condition: This symptom occurs when the card is tested in an ESS (Environment Stress
Screen) low temperature lab.