Description: When the firewall resumes normal traffic level, the occupied memory
cannot be reclaimed in time.
Problem 4 HSD96862
Condition: Enable the user log function.
Description: The user log data sent to the log host is not complete, and contains
20-byte invalid data.
Problem 5 HSD97292
Condition: None
Description: The firewalls internal 10GE interface rate statistics are incorrect.
Resolved problems in
SECBLADEII-CMW520-F3171P02
Problem 1 HSD95817
Condition: None
Description: If the memory occupation is too high, processes may lock each other,
resulting in a device reboot.
Problem 2 HSD93926
Condition: None
Description: After you failed to modify an address group object, clicking the interzone
policy in the navigation tree will result in an abnormal device reboot.
Problem 3 HSD92124
Condition: None
Description: After FIN packets pass through the firewall in opposite directions, the
firewall will drop the FIN packets in one direction.
Problem 4 HSD94491
Condition: None
Description: Importing IP address and address group resources results in device stack
reboots.
Problem 5 HSD94379
Condition: None
Description: Connect an SNMPTest to the firewall. The SHA-3DES mode results in a
device fault.
Problem 6 HSD95197
Condition: None
Description: After the memory occupation of sessions rises to a peak, the occupied
memory is not released even if the number of sessions decreases.