Installation and Getting Started Guide for HP 600/610/620/630 RPS/EPS 2011-04
5-28
Installing and Connecting the HP Redundant / External Power Supplies
Recommended Connection Topologies
Figure 5-14. Example connecting 2 switches to EPS ports on an HP 600 RPS/EPS
Limitations
In the illustration above, the two switches connected to the HP 600 RPS/EPS
are limited to 204 W of power on each EPS port. If a switch tries to draw more
than 204 W of power from the HP 600 RPS/EPS, an over-current condition
occurs and the EPS port connected to that switch shuts down. To supply more
than 204 W on one EPS port, the other port must first be disconnected. The
maximum power that can be provided when only one EPS port is connected
to a switch is 408 W.
EPS 1
RPS 5
R5
RPS 3
R3R1
Power Status
RPS 1
R2
RPS 2
RPS 4
R4
R6
RPS 6
E1
E2
EPS 2
Device
Connected
Powe r
Status
Device Connected
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
HP 600 RPS/EPS
HP 2650 switches
AC Power
EPS cables