Installation and Getting Started Guide for HP 600/610/620/630 RPS/EPS 2011-04

5-23
Installing and Connecting the HP Redundant / External Power Supplies
Installation Procedures
6. Verify Correct Operation
HP 600 RPS/EPS and HP 610 EPS
When the HP 600 RPS/EPS or HP 610 EPS is mounted in its location and
powered on, you should first verify that it is working properly by checking the
unit’s LEDs.
Check the LEDs on the unit as described below.
When the unit is powered on, it performs its diagnostic self test. The self test
takes approximately 5 seconds to complete.
LED Behavior:.
During the self test:
Initially, all the unit and port LEDs are on and stay on for most of the
duration of the self test.
Most of the LEDs go off and then may come on again during phases
of the self test.
Power
Fault
Power Status
E2
Device Connected
E1
EPS Port Status
R6 R5
R4 R3
R2
R1
Device Connected
RPS Port Status
Power Status
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
Fan/Temp
Status
Power
Fault
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
Fan/Temp Status
Internal Power Status
EPS A1
A2A1
EPS A2
EPS Ports: 50 V
8.3 A max per port p
EPS Ports Pair A
(
408 W total for PoE applications
)
Power
Status
Device
Connected
EPS Backup Power Ports Status
In Ready
Out Ready
HP ProCurve
610 EPS
J8169A
Fan/Temp Status LED
RPS port LEDs
Power and
Fault LEDs
EPS port LEDs
Fan/Temp
Status LED
Power and
Fault LEDs
EPS port LEDs
EPS Backup Power port LEDs
HP 600 RPS/EPS
HP 610 EPS
Internal Power
Status LED