Installation and Getting Started Guide for HP 600/610/620/630 RPS/EPS 2011-04
5-20
Installing and Connecting the HP Redundant / External Power Supplies
Installation Procedures
Connecting the HP 620 RPS and EPS Ports to Switches
To co nn ect:
Push the RPS or EPS cable plug into the
desired port until the thumb screws
engage with the screw holes in the unit.
Tighten the thumb screws.
When power is on for the HP 620 RPS/
EPS and for the connected switch, the
Device Connected LED should go on to
confirm a powered-on switch is at the
other end of the cable.
If the Device Connected LED does not go
on when the cable is connected to the
port, see Diagnosing with the LEDs in
chapter 6, “Troubleshooting.”
To disconnect:
Unscrew the thumb screws on the plug and pull the plug out of the port.
Note Refer to “EPS Port Operation” on page 3-5 for detailed information and on PoE
power usage, and to “Limitations” on page 5-39 for information on maximum
available PoE power.
RPS or EPS Cable:
• Only use the cables supplied with the unit