3Com Switch 7750 Configuration Guide

Telnet Configuration with Authentication Mode Being Password 57
Telnet protocol is supported.
The screen can contain up to 30 lines.
The history command buffer can contain up to 20 commands.
The timeout time of VTY 0 is 6 minutes.
Network diagram
Figure 9 Network diagram for Telnet configuration (with the authentication mode being
password)
Configuration procedure
# Enter system view.
<SW7750> system-view
# Enter VTY 0 user interface view.
[SW7750] user-interface vty 0
# Configure to authenticate users logging into VTY 0 using the local password.
[SW7750-ui-vty0] authentication-mode password
# Set the local password to 123456 (in plain text).
[SW7750-ui-vty0] set authentication password simple 123456
# Specify commands of level 2 are available to users logging into VTY 0.
[SW7750-ui-vty0] user privilege level 2
# Configure Telnet protocol is supported.
[SW7750-ui-vty0] protocol inbound telnet
# Set the maximum number of lines the screen can contain to 30.
[SW7750-ui-vty0] screen-length 30
# Set the maximum number of commands the history command buffer can store
to 20.
[SW7750-ui-vty0] history-command max-size 20
User PC running Telnet
Ethernet
Ethernet2/0/1