9.6 HP Pay per use Utility Meter II Software Installation and Configuration Guide (October 2012)

Installation and Configuration Guide
Chapter 3: Configuring Devices
where model is the model of the 3PAR array, serial is the serial number of the array, and
IPAddress is either the fully qualified domain name or IP address of the 3PAR InForm OS
managing the device. The -info parameter is optional.
3. When prompted, enter the password for the specified userName required to log on to the
3PAR Inform OS server.
After entering the password, you should see the following output:
Device deviceName added successfully.
4. Verify the 3PAR array was added by listing the devices that are being monitored by the Utility
Meter:
$ umadmin list
List of devices -
Device Name = deviceName
Type = URS3PAR
Address = IPAddress
Device ID = deviceID
Info = info
Model = model
Serial = serial
You should see the 3PAR array that you added in Step 2 listed.
Modify Devices
Modifying a PPU WBEM Partition/Server
Modify a PPU WBEM Partition/Server from the GUI
To modify a PPU WBEM Partition/Server using the GUI, complete the following steps:
1. Open a browser and enter the Utility Meter's fully qualified domain name into the address bar.
2. Log on to the Utility Meter as user umeter (default password: h.lnxmtr).
3. Select the Device Management tab, select the device to be modified and click Modify
Device.
4. The following information can be modified for a PPU WBEM Partition/Server using the Modify
Devices form:
HP Pay per use Utility Meter II Software (9.6)Page 32 of 65