8.16 HP Utility Meter User's Guide (June 2010)
1. Log in as root.
2. Execute the following command:
# /opt/SSSU/sssu
You should see output that is similar to the following displayed, where the line beginning with
"Version:" is the SSSU version:
SSSU for HP StorageWorks Command View EVA
Version: 9.0.0
If you do not see version 9.0.0 or 9.2.0 of the CV EVA SSSU software displayed, install the correct version
of the SSSU software by following the instructions in Section 2.7: “URS EVA Only – Installing the CV EVA
SSSU Software”. Repeat this procedure with other directory paths if more than one version of SSSU is installed
on the Utility Meter.
If you see the correct version of the CV EVA SSSU software displayed, then you have successfully verified
that the correct version of the CV EVA SSSU software is installed and no further action is necessary.
4.8.5 XP Only – Verifying the Correct Version of CV XP AE CLI is Installed
Utility Ready Storage (URS) installations that have XP devices configured in the Utility Meter must have version
6.2 or 6.3 of the HP StorageWorks XP Command View Advanced Edition Command Line Interface (XP CLI)
software installed on the Utility Meter.
Perform the following procedure on the Utility Meter to verify that version 6.2 or 6.3 of the XP CLI software
is installed on the Utility Meter for URS XP installations. This procedure assumes the XP CLI software is installed
in /opt/CLI. Because you can install the XP CLI software in any directory on the Utility Meter, this directory
can be different. On the Utility Meter:
1. Log in as root.
2. Execute the following commands:
# /opt/CLI/hdvmcli.sh 2>&1 | grep -i version
# /usr/bin/grep -i version /tmp/cli.out
You should output that is similar to the following displayed:
Device Manager CLI version "6.3.0-00"
If you do not see version 6.2 or 6.3 of the XP CLI software displayed, install the correct version of the XP
CLI software by following the instructions in Section 2.8: “URS XP Only – Installing the CV XP AE CLI Software”.
Repeat this procedure with other directory paths if more than one version of XP CLI is installed on the Utility
Meter.
If you see the correct version of the CLI displayed, then you have successfully verified that the correct version
of the CLI is installed and no further action is necessary.
4.8.6 VLS Only – Verifying the Correct Version of VLS Firmware is Installed
Utility Ready Storage (URS) installations that have VLS devices configured in the Utility Meter must have
firmware version 2.3.1 or 3.3.0 installed.
Perform the following procedure on the Utility Meter to verify that firmware version 2.3.1 or 3.3.0 is installed
for URS VLS installations.
1. Log on to the web interface of the VLS device and look for the words Software version: on the home
page of the web interface.
88 Verifying Utility Meter Operation