8.16 HP Utility Meter User's Guide (June 2010)
for a command line install or
/usr/sbin/swinstall -s <path-to-depot>
for a GUI install. Make sure to select all subpackages in the depot in a GUI install.
The Utility Meter software swinstall takes less than 5 minutes. If you are installing using the
swinstall GUI you will see the installation temporarily pause for a few minutes at 100% Complete,
specifying it is in the “Configure” phase. Do not interrupt the processing in the swinstall GUI—wait
until it finishes.
8. Follow the instructions in Section 2.5.3: “Completing the Utility Meter Software Installation” to complete
and verify the Utility Meter software installation has been successful.
2.5.2 Installing the Utility Meter Software from the Software Media (CD or DVD)
Follow this procedure to install the Utility Meter software from the appropriate (HP-UX 11i v2, or 11i v3)
HP-UX Application Software
media (CD or DVD):
1. On the Utility Meter, log in as root.
2. Insert the
HP-UX Application Software
media into the optical drive (CD or DVD) on the Utility Meter
system. Alternatively, the
HP-UX Application Software
media may be loaded into a drive on another
system running HP-UX, or a copy of the
HP-UX Application Software
media may be on another system,
running HP-UX.
3. If using the locally attached drive, do the following to install the Utility Meter software from the media;
otherwise, go to Step 4:
a. Start the swinstall installation GUI by executing the following command:
/usr/sbin/swinstall
b. In the Specify Source window, click the Find Local CD button.
c. In the SD Install window, mark the Utility Meter software (T2805AA or T5462A) bundle and
all dependent software for installation, and install the bundle.
d. After the Utility Meter software installation is complete, close the swinstall GUI (or TUI).
You are finished with the Utility Meter software installation and can skip Step 4.
4. If using a software depot on a remote system, do the following:
a. Determine the hostname of the system containing the software depot.
b. Determine the pathname of the software depot on the above system.
c. Using the above information, install the Utility Meter software with the following swinstall
command:
• For PPU installations:
/usr/sbin/swinstall –s hostname:pathname T2805AA
• For URS installations:
/usr/sbin/swinstall –s hostname:pathname T5462A
where hostname is determined in Step 4.a and pathname is determined in Step 4.b.
The Utility Meter software swinstall takes less than 5 minutes. If you are installing using the swinstall
GUI you will see the installation temporarily pause for a few minutes at 100% Complete, specifying it is
in the “Configure” phase. The configuration is still going on so do not interrupt the processing in the
swinstall GUI—wait until it finishes.
After installing the Utility Meter software, follow the instructions in “Completing the Utility Meter Software
Installation” to complete and verify the Utility Meter software installation has been successful.
2.5.3 Completing the Utility Meter Software Installation
After you have installed the Utility Meter software, perform the following steps to complete the software
installation:
2.5 Obtaining and Installing the Utility Meter Software 29