8.15 HP Utility Meter User's Guide (January 2010)
Table Of Contents
- HP Utility Meter User's Guide for version 8.15
- Table of Contents
- About This Document
- 1 Introduction
- 2 Installing and Configuring the Utility Meter Software
- 2.1 Overview
- 2.2 Skills Required
- 2.3 Before Going to the Customer Site
- 2.4 Configuring the HP-UX System Parameters
- 2.5 Obtaining and Installing the Utility Meter Software
- 2.6 Configuring the Utility Meter Parameters
- 2.7 URS XP Only – Installing the CV XP AE CLI Software
- 2.8 URS EVA Only – Installing the CV EVA SSSU Software
- 2.9 URS HP/Brocade SAN Switch Only – Installing the SMI-S Agent Software
- 2.10 URS Cisco SAN Switch Only – Enabling the CIM Server
- 2.11 Email Hostname Masquerading
- 2.12 Configuring PPU Partitions and URS Devices
- 2.13 Verifying the Utility Meter Operation
- 2.14 Completing the Utility Meter Installation and Configuration
- 2.15 Upgrading the Utility Meter Software to Version 8.15
- 3 Performing Utility Meter Tasks
- 4 Verifying Utility Meter Operation
- 4.1 Verifying the Utility Meter Hardware is Operational
- 4.2 Verifying the Utility Meter Software is Operational
- 4.3 Verifying the CIM Server Software Is Operational
- 4.4 Verifying Connectivity from the Utility Meter to HP
- 4.5 Verifying the Data Acquisition Server is Running
- 4.6 Verifying the Utility Meter Data Transport Method
- 4.7 Verifying a PPU Partition
- 4.8 Verifying a Storage Device
- 4.8.1 Verifying a Device is Configured in the Utility Meter
- 4.8.2 Verifying a Device is Connected to the Utility Meter
- 4.8.3 Verifying the Connection from the Utility Meter to HP
- 4.8.4 XP Only – Verifying the Correct Version of CV XP AE CLI is Installed
- 4.8.5 EVA Only – Verifying the Correct Version of CV EVA SSSU is Installed
- 4.9 Verifying a SAN Device
- 5 Troubleshooting the Utility Meter
- A Site Preparation Form for Pay Per Use
- B Site Preparation Form for Utility Ready Storage
- C Data Fields Sent from the Utility Meter to HP
- Glossary
- Index

4. Configure the Utility Meter software parameters by using the Utility Meter application GUI. For more
information about the Utility Meter configuration, see Section 2.6: “Configuring the Utility Meter
Parameters”.
5. If there are Utility Ready Storage (URS) XP devices that need to be metered, install a supported version
of the HP StorageWorks XP Command View Advanced Edition Command Line Interface (CLI) software.
For more information about this type of installation, see Section 2.7: “URS XP Only – Installing the CV
XP AE CLI Software”.
6. If there are Utility Ready Storage (URS) EVA devices that need to be metered, install a supported version
of the HP StorageWorks Storage System Scripting Utility (SSSU) software. For more information about
this type of installation, see Section 2.8: “URS EVA Only – Installing the CV EVA SSSU Software”.
7. If there are URS XP or EVA devices that need to be metered by the Utility Meter, configure the devices
in the Utility Meter GUI. For more information about this type of configuration, see Section 3.5: “Utility
Meter Devices Tasks”.
8. If there are URS SAN switch devices that need to be metered by the Utility Meter, configure the devices
in the Utility Meter GUI. For more information about this type of configuration, see Section 3.5: “Utility
Meter Devices Tasks”.
9. If there are Pay per use (PPU) server partitions that need to be metered by the Utility Meter, configure
every PPU partition by adding the partitions as a PPU WBEM Partition/Server in the Utility Meter GUI
or configure the partitions with the appropriate PPU Agent software command. For more information
about configuring partitions with PPU Agent software, see Section 7: “Related Documents” for a link to
the
PPU User's Guide
.
10. Verify the Utility Meter operation (see Chapter 4: “Verifying Utility Meter Operation”).
2.2 Skills Required
The Utility Meter software installation and configuration requires the following skills:
• HP-UX operating system concepts, commands, and configuration
• PPU Agent software commands and configuration (for PPU installations that use PPU Agent software)
• CIM commands such as cimserver and cimprovider
• Disk array configuration and Command View product experience (for URS storage array metering)
• Experience with SAN switches of the “Director” class from HP/Brocade and Cisco (for URS SAN switch
metering)
• Experience with Brocade SMI-S Agent software (for URS SAN switch metering)
• sendmail experience – see the
HP-UX Mailing Services Administrator's Guide
at:
http://www.docs.hp.com/en/netcom.html#Internet Services.
2.3 Before Going to the Customer Site
For the initial Utility Meter installation and configuration, make sure you have the following items before
going to the customer site:
• The completed
Utility Meter Site Preparation Form
.
For details, see Appendix A “Site Preparation Form for Pay Per Use” or Appendix B “Site Preparation
Form for Utility Ready Storage”. The Site Preparation Form contains the networking details and Utility
Meter information you need to complete the Utility Meter installation. You must work with the customer
to complete this preparation form.
• Access to the Utility Meter system.
Access is needed to install and configure the Utility Meter software. Note that the Utility Meter system
is ordered without a keyboard, mouse and monitor. After installation, the keyboard, mouse, and video
are not required. Options to access the Utility Meter system include:
• Customer provides keyboard, mouse and monitor
• Customer provides access via KVM switch
26 Installing and Configuring the Utility Meter Software