8.15 HP Utility Meter User's Guide (January 2010)
Table Of Contents
- HP Utility Meter User's Guide for version 8.15
- Table of Contents
- About This Document
- 1 Introduction
- 2 Installing and Configuring the Utility Meter Software
- 2.1 Overview
- 2.2 Skills Required
- 2.3 Before Going to the Customer Site
- 2.4 Configuring the HP-UX System Parameters
- 2.5 Obtaining and Installing the Utility Meter Software
- 2.6 Configuring the Utility Meter Parameters
- 2.7 URS XP Only – Installing the CV XP AE CLI Software
- 2.8 URS EVA Only – Installing the CV EVA SSSU Software
- 2.9 URS HP/Brocade SAN Switch Only – Installing the SMI-S Agent Software
- 2.10 URS Cisco SAN Switch Only – Enabling the CIM Server
- 2.11 Email Hostname Masquerading
- 2.12 Configuring PPU Partitions and URS Devices
- 2.13 Verifying the Utility Meter Operation
- 2.14 Completing the Utility Meter Installation and Configuration
- 2.15 Upgrading the Utility Meter Software to Version 8.15
- 3 Performing Utility Meter Tasks
- 4 Verifying Utility Meter Operation
- 4.1 Verifying the Utility Meter Hardware is Operational
- 4.2 Verifying the Utility Meter Software is Operational
- 4.3 Verifying the CIM Server Software Is Operational
- 4.4 Verifying Connectivity from the Utility Meter to HP
- 4.5 Verifying the Data Acquisition Server is Running
- 4.6 Verifying the Utility Meter Data Transport Method
- 4.7 Verifying a PPU Partition
- 4.8 Verifying a Storage Device
- 4.8.1 Verifying a Device is Configured in the Utility Meter
- 4.8.2 Verifying a Device is Connected to the Utility Meter
- 4.8.3 Verifying the Connection from the Utility Meter to HP
- 4.8.4 XP Only – Verifying the Correct Version of CV XP AE CLI is Installed
- 4.8.5 EVA Only – Verifying the Correct Version of CV EVA SSSU is Installed
- 4.9 Verifying a SAN Device
- 5 Troubleshooting the Utility Meter
- A Site Preparation Form for Pay Per Use
- B Site Preparation Form for Utility Ready Storage
- C Data Fields Sent from the Utility Meter to HP
- Glossary
- Index

2 Installing and Configuring the Utility Meter Software
2.1 Overview
This chapter provides information and procedures for two different audiences:
• HP Services representatives who initially install and configure the Utility Meter software. It is recommended
that they read and perform all procedures in this chapter.
• Utility Meter customers with an existing Utility Meter who reconfigure HP-UX system settings or reinstall
or reconfigure existing Utility Meter software. They can perform the following tasks:
• Reconfigure HP-UX system parameters (see Section 2.4: “Configuring the HP-UX System
Parameters”).
• Reinstall the Utility Meter software (see Section 2.5: “Obtaining and Installing the Utility Meter
Software”).
• Reconfigure the Utility Meter parameters (see Section 2.6: “Configuring the Utility Meter
Parameters”).
• Add, modify, or remove an EVA disk array in an existing Utility Meter (see Section 3.5.1:
“Configure a Device (Add Device)”).
• Add, modify, or remove an XP disk array in an existing Utility Meter (see Section 3.5.1: “Configure
a Device (Add Device)”).
• Add, modify, or remove a PPU WBEM Partition/Server in an existing Utility Meter (see
Section 3.5.1.3: “Add a PPU WBEM Partition/Server”).
• Add, modify, or remove a Cisco SAN switch in an existing Utility Meter (see Section 3.5.1.4:
“Add a Cisco SAN Switch”).
• Add, modify, or remove an HP/Brocade SAN switch into an existing Utility Meter (see
Section 3.5.1.5: “Add an HP/Brocade SAN Switch”).
This installation and configuration chapter assumes:
• The Utility Meter hardware has been physically installed, powered on and provided with the required
physical network connections.
• The appropriate version of HP-UX has been installed and configured.
• The network has been properly configured, including any firewall configuration.
• For Utility Ready Storage (URS) installations, the appropriate HP StorageWorks Command View
application software is installed and configured to manage all URS devices. (Note that the Command
View software is installed on hardware separate from the Utility Meter).
• For HP/Brocade SAN switch metering the Brocade SMI-S Agent needs to be installed on a separate
server. For Cisco switches the CIM server on them needs to be enabled.
• For PPU installations using WBEM to pull reports from the metered partition or server, the appropriate
WBEM software must be installed prior to adding it in the GUI. (Note that the WBEM software is
installed on the metered partition or server, not on the Utility Meter).
The HP-UX operating system is pre-loaded onto the Utility Meter hardware at the HP factory. For HP services
representatives who are performing the initial Utility Meter setup, the initial Utility Meter setup consists of the
following main steps:
1. Have the customer fill out Appendix A “Site Preparation Form for Pay Per Use” or Appendix B “Site
Preparation Form for Utility Ready Storage”. Make sure that this information is accurate and up to date.
2. At first boot of the Utility Meter, fill out the screens presented for items such as: hostname, IP address,
network mask, and DNS servers. This information is taken from the form mentioned in Step 1.
3. Install the Utility Meter software. For information about this installation, see “Obtaining and Installing
the Utility Meter Software”. Note that a reboot of the Utility Meter system and verification of the Utility
Meter processes and services are required.
2.1 Overview 25