HPOS 3.5 - Tuning Windows to Improve Stability
HP Output Server 3.5 1
Technical Note
Tuning Windows Parameters to Improve
Stability in HP Output Server 3.5
This technical note describes how to improve the job submission rate and stability of HP Output Server 3.5 when
installed on Windows operating systems.
NOTE: HP recommends tuning a few Windows-specific parameters as described in the sections
below before deploying HP Output Server 3.5 in your production environment. This
tuning helps achieve greater stability and reliability for HP Output Server 3.5.
Problem
When HP Output Server 3.5 is installed on a machine running the Windows operating system, different kinds of
errors may occur when jobs are submitted to a large number of destinations from multiple clients. These errors affect
the job submission rate and also lower the stability of the server. The overall performance of HP Output Server 3.5
suffers.
The errors might differ across scenarios. Examples of various scenarios and errors are described below:
Table 1-1. Scenarios and Errors that may Occur on the Windows Operating System when HP Output Server
3.5 is Installed
Scenario Configuration Operating
system
Servers Clients Destination Results Errors
1 Hardware:
HP DL560
model
5GB RAM
Four-2.2 GHz
Xeon
processors
Windows
2003
Enterprise
Edition
10 DLM
16 JQM
150 DSM
14
(remote)
4500 ps and
4500 pcl
272 jobs
per
minute,
494247
jobs
delivered,
776 job
failures
“[error
000b41d6]
Exception
caught while
waiting for
transformer
to finish
(Agent
exited with
error status
2304)”