FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

F
F-24
E/OS SNMP Support Manual
Fabric Element Management MIB
Status mandatory
Description The current operational status of the FxPort. The testing(3) indicates
that no operational frames can be passed. If
fcFxPortPhysAdminStatus is offline(2) then fcFxPortPhysOperStatus
should be offline(2). If fcFxPortPhysAdminStatus is changed to
online(1) then fcFxPortPhysOperStatus should change to online(1) if
the FxPort is ready to accept Fabric Login request from the attached
NxPort; it should proceed and remain in the link-failure(4) state if
and only if there is a fault that prevents it from going to the online(1)
state.
Sequence
::= { fcFxPortPhysEntry 4 }
fcFxPortPhysLastChange
Syntax TimeTicks
Access read-only
Status mandatory
Description The value of sysUpTime at the time the FxPort entered its current
operational status. A value of zero indicates that the FxPort's
operational status has not changed since the agent last restarted.
Sequence
::= { fcFxPortPhysEntry 5 }
fcFxPortPhysRttov
Syntax MilliSeconds
Access read-only -- instead of read-write
Status mandatory
Description The Receiver_Transmitter_Timeout value of the FxPort. This is used
by the receiver logic to detect Loss of Synchronization.
Sequence
::= { fcFxPortPhysEntry 6 }