Event Group
B-45
FC Management MIB
connUnitLinkPortNumberX
Syntax INTEGER
Access read-only
Status mandatory
Description The port number on the unit specified by connUnitLinkNodeIdX if
known, otherwise -1. If the value is nonnegative then it will be equal
to connUnitPortPhysicalNumber.
Sequence
::= { connUnitLinkEntry 4 }
connUnitLinkPortWwnX
Syntax FcGlobalId
Access read-only
Status mandatory
Description The port WWN of the unit specified by connUnitLinkNodeIdX if
known, otherwise 16 octets of binary 0.
Sequence
::= { connUnitLinkEntry 5 }
connUnitLinkNodeIdY
Syntax OCTET STRING (SIZE(16))
Access read-only
Status mandatory
Description The node WWN of the unit at the other end of the link. If the node
WWN is unknown and the node is a connUnit in the responding
SNMP agency then the value of this object MUST BE equal to its
connUnitID.
Sequence
::= { connUnitLinkEntry 6 }
connUnitLinkPortNumberY
Syntax INTEGER
Access read-only
Status mandatory