FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

B
Connectivity unit group
B-9
FC Management MIB
The value assigned to a given conectivity unit SHOULD be persistent
across agent and unit resets. It SHOULD be the same as
connUnitGlobalId if connUnitGlobalId is known and stable.
Sequence
::= { connUnitEntry 1 }
connUnitGlobalId
Syntax FcGlobalId
Access read-only
Status mandatory
Description An optional global-scope identifier for this connectivity unit. It MUST
be a WWN for this connectivity unit or 16 octets of value zero. WWN
formats requiring fewer than 16 octets MUST be extended to 16 octets
with trailing zero octets, Left justified, zero filled, If a WWN is used
for connUnitId, the same WWN MUST be used forconnUnitGlobalId.
When a non-zero value is provided, it SHOULD be persistent across
agent and unit resets. It SHOULD be globally unique. It SHOULD be
one of these FC-PH/PH3 formats:
IEEE (NAA=1)
IEEE Extended (NAA=2)
IEEE Registered (NAA=5).
IEEE Registered extended (NAA=6).
Use of the IEEE formats allows any IEEE-registered vendor to assure
global uniqueness independently. The following are some references
on IEEE WWN formats:
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.htm
l
If one or more WWNs are associated with the connUnit via other
management methods, one of them SHOULD be used for
connUnitGlobalId.
If there is not a WWN assigned specifically to the connUnit, there is
some merit, though not a requirement, to using a WWN assigned to
(one of) its permanently attached FC/LAN interface(s). This can not
risk uniqueness, though.