Fibre Alliance MIB
2-113
McDATA SNMP Support
bypassed value (8) means that the port has been manually or
automatically isolated from the loop or fabric; the other values are
essentially self-explanatory. Any value for this object may co-exist
with any value for the
fcConnUnitPortState object.
The values are defined as unknown (1), unused (2), ok (3), warning
(4), failure (5), notParticipating (6), initializing (7), bypassed (8).
FcConnUnitPortTransmitterType
Type INTEGER
Product Mapping This is mapped from the port technology as not present and serial
indicate unknown(1), optical sw1g and optical sw2g indicate
shortwave(4). Optical lw1g and optical lw2g indicate longwave(5),
copper db9 and copper amp indicate copper(6).
Access R
Description The technology of the port transceiver. The values are defined as
unknown (1), other (2), unused (3), shortwave (4) longwave (5),
copper (6), and scsi (7), longwaveNoOFC (8), shortwaveNoOFC (9),
longwaveLED (10),
fcConnUnitPortModuleType
Type INTEGER
Product Mapping If the port is not installed, return gbicNotInstalled(8). Otherwise
return smallFormFactor(9).
Access R
Description The module type of the port connector. This object refers to the
hardware implementation of the port. The embedded value (4)
means ‘fixed’ (e.g., oneXnine).
The values are defined as unknown (1), other (2), gbic (3), embedded
(4), glm(5), gbicSerialId (6), gbicNoSerialId (7), gbicNotInstalled (8),
smallFormFactor (9).
FcConnUnitPortWwn
Type FcNameId
Product Mapping World Wide Name of the port.
Access R