FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)
B
Event Group
B-43
FC Management MIB
connUnitLinkTable
Syntax SEQUENCE OF ConnUnitLinkEntry
Access not-accessible
Status mandatory
Description A list of links know to this agent from this connectivity unit to other
connectivity units.
Sequence
::= { connSet 12 }
connUnitLinkEntry
Syntax ConnUnitLinkEntry
Access not-accessible
Status mandatory
Description An entry describing a particular link to another.
INDEX { connUnitLinkUnitId, connUnitLinkIndex }
Sequence
::= { connUnitLinkTable 1 }
ConnUnitLinkEntry ::=
SEQUENCE {
connUnitLinkUnitId FcGlobalId,
connUnitLinkIndex INTEGER,
connUnitLinkNodeIdX OCTET STRING,
connUnitLinkPortNumberX INTEGER,
connUnitLinkPortWwnX FcGlobalId,
connUnitLinkNodeIdY OCTET STRING,
connUnitLinkPortNumberY INTEGER,
connUnitLinkPortWwnY FcGlobalId,
connUnitLinkAgentAddressY OCTET STRING,
connUnitLinkAgentAddressTypeY INTEGER,
connUnitLinkAgentPortY INTEGER,