FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

A
A-40
E/OS SNMP Support Manual
Fibre Alliance MIB
fcConnUnitLinkIndex
Syntax Unsigned32
Max-Access read-only
Status current
Description This value is used to create a unique value for each entry in the link
table with the same fcConnUnitId. The value can only be reused if it
is not currently in use and the value is the next candidate to be used.
This value is allowed to wrap at the highest value represented by the
number of bits. This value is reset to zero when the system is reset
and the first value to be used is 1.
Sequence
::= { fcConnUnitLinkEntry 1 }
fcConnUnitLinkNodeIdX
Syntax OCTET STRING (SIZE(64))
Max-Access read-only
Status current
Description The node WWN of the unit at one end of the link. If the node WWN is
unknown and the node is an fcConnUnit in the responding agent
then the value of this object MUST be equal to its fcConnUnitId.
Sequence
::= { fcConnUnitLinkEntry 2 }
fcConnUnitLinkPortNumberX
Syntax Integer32
Max-Access read-only
Status current
fcConnUnitLinkPortWwnY OCTET STRING,
fcConnUnitLinkAgentAddressY OCTET STRING,
fcConnUnitLinkAgentAddressTypeY Unsigned32,
fcConnUnitLinkAgentPortY Unsigned32,
fcConnUnitLinkUnitTypeY FcUnitType,
fcConnUnitLinkConnIdY OCTET STRING }