FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)
A
FA MIB
A-21
Fibre Alliance MIB
Description A textual identification of the sensor intended primarily for operator
use.
Sequence
::= { fcConnUnitSensorEntry 2 }
fcConnUnitSensorStatus
Syntax INTEGER {
unknown(1),
other(2),
ok(3),
warning(4),
failed(5) }
Max-Access read-only
Status current
Description The status indicated by the sensor.
Sequence
::= { fcConnUnitSensorEntry 3 }
fcConnUnitSensorInfo
Syntax SnmpAdminString
Max-Access read-only
Status current
Description Miscellaneous static information about the sensor such as its serial
number.
Sequence
::= { fcConnUnitSensorEntry 4 }
unknown (1) the unit cannot determine the status
other (2) the status does not fit any of the remaining values
ok (3) indicates good status
warning (4) indicates the unit needs attention
failed (5) indicates the unit is non-functional"