FW 05.01.00 and SW 07.01.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches (AA-RQ7AD-TE, June 2003)

config.switch.edTOV
97CLI Reference Guide for Directors and Edge Switches
Syntax
edTOV timeoutValue
Purpose
This command sets the E_D_TOV for the switch.
Description
The switch must be set offline before this command is entered.
Special care should be used when scripting this command due to its relationship
with R_A_TOV.
Parameters
This command has one parameter:
Command Example
Root> config switch edTOV 4
config.switch.edTOV
timeoutValue Specifies the new E_D_TOV value.
The units for this value are tenths of a second.
This parameter must be an integer in the range
2–600 (0.2 second to 60 seconds), and it must be
smaller than the R_A_TOV.