FW 05.01.00 and SW 07.01.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches (AA-RQ7AD-TE, June 2003)
CLI Commands
94 CLI Reference Guide for Directors and Edge Switches
Syntax
bbCredit bbCreditValue
Purpose
This command sets the buffer-to-buffer credit value for all ports, except those
ports configured for extended distance. (The Edge Switch 2/24 does not accept
this command.)
Description
The switch must be set offline before this command is entered.
Parameters
This command has one parameter:
Command Example
Root> config switch bbCredit 2
config.switch.bbCredit
bbCreditValue Specifies the new buffer-to-buffer credit value.
This parameter must be an integer in the range
1–60.