2. Examine what is installed versus what is available in the Firmware Baseline.
Managing Virtual Connect Firmware
HP OneView provides the ability to manage Virtual Connect firmware from multiple locations; at the Logical Interconnect or
Enclosure level. Managing Virtual Connect firmware at the Logical Interconnect would be used for those times where only VC
firmware requiring updating.
1. Select Logical Interconnects from the Top Level Menu.
2. In the Logical Interconnects view, validate the [ENC-Name]-LI Logical Interconnect is selected, then the Actions menu
select Update Firmware.
3. On the Update Firmware on [ENC-NAME]-LI window, select the Firmware Baseline, and select Update Firmware (stage +
activate) action. The other two options are for staging firmware to initiate a manual activation of the Virtual Connect