HP Insight Control for VMware vCenter Server Installation Guide Abstract This document contains detailed instructions for installing, upgrading, and removing HP Insight Control for VMware vCenter Server. The intended audience is system administrators who are experienced in virtual and physical IT infrastructure administration and understand server virtualization, storage, and networking concepts.
© Copyright 2012, 2013 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Contents 1 Overview..................................................................................................4 Server Module for vCenter features.............................................................................................7 Storage Module for vCenter features...........................................................................................7 2 Installing, upgrading, and removing the software............................................9 Insight Control for vCenter licensing..
1 Overview HP Insight Control for VMware vCenter Server (Insight Control for vCenter) is a single integrated application that you use to manage ProLiant servers and/or HP storage systems. The application consists of three modules. The core module is required along with one or two optional components: the Server Module for vCenter and Storage Module for vCenter. Core Module Provides the framework required by the Server Module for vCenter and Storage Module for vCenter.
Figure 1 HP Insight Management Overview — vSphere Client view Figure 2 HP Insight Management Overview — vSphere Web Client view The Server Module for vCenter: • Provides inventory and status information. This information is collected from HP ProLiant tools such as Onboard Administrator, iLO, Virtual Connect Manager, HP ESXi Offline Bundle for VMware ESXi, and HP Management Agents for VMware ESX.
• Provides a method for software and firmware deployment1. • Provides graphical status indications collected from the HP ProLiant tools, and a graphical view of the end-to-end network for each host1. • Supports HP VMware ESXi Smart Components2. • Provides the ability to configure vSwitches on a host based on the networks available in the Virtual Connect profile.
Server Module for vCenter features Insight Control for vCenter provides HP Insight Control hardware management capabilities to administrators, enabling comprehensive monitoring, remote control, and power optimization from the VMware vCenter Server console.
From the vSphere Client, the Storage Module for vCenter enables you to do the following: • Monitor the status and health of HP storage arrays. • Understand the relationships between physical storage and virtual objects.
2 Installing, upgrading, and removing the software This chapter provides the procedures to install, upgrade, and remove Insight Control for vCenter. Insight Control for vCenter licensing Insight Control for vCenter is licensed as part of HP Insight Control. Insight Control for vCenter does not have separate license keys. You must have one Insight Control license for each HP ProLiant server managed by Insight Control for vCenter. The Storage Module for vCenter does not require this license.
Insight Control for vCenter requirements This section describes the hardware, software, and network connectivity requirements for Insight Control for vCenter.
Table 3 Network connectivity requirements Insight Control for vCenter module Specification All Insight Control for vCenter modules Network connectivity to the following: • Systems running vCenter Server • Systems running VMware vSphere Client • ESXi host system Server Module for vCenter Network connectivity to the following: • HP SIM (required for SIM-enabled functionality) • All instances of iLO that you want to manage • All Onboard Administrator modules that you want to manage • All Virtual Connect m
Table 3 Network connectivity requirements (continued) Insight Control for vCenter module Specification • HP MSA P2000 G3 requires: ◦ Network connectivity to the storage system’s management port ◦ SMI-S provider must be enabled on the storage system To verify, log into the array. Select Configure→Services→Management to verify that the SMS Enabled box is selected.
Optional components Table 4 (page 13) describes the benefits of using optional components.
3. Download the installer: a. Go to the HP Insight Management downloads website: http://www.hp.com/go/insightupdates b. c. Click Download the latest Insight Management DVD ISO images. Follow the instructions to download the software. You must sign up for an HP Passport to gain access. The installer is in executable (.exe) file format. NOTE: The software installer is also available at https://h20392.www2.hp.com/portal/ swdepot/displayProductInfo.do?productNumber=HPVPR. 4. 5.
Table 6 Insight Control for vCenter default ports (installing Server module only) ◦ Port Default value HP UIM Port 3500 HP UIM DB Port 3501 HP Server Port 3502 HP Common Services Port 3503 HP Common Services WBEM Port 3504 Installation directory: C:\Program Files (x86)\HP • Select Custom if you want to set different values for data import, ports, or the installation location. The Module Selection dialog opens. 9.
11. Do one of the following: • If you have an FTP proxy server, select Yes, enter the proxy server name or IP address and the port number, and then click Next. • If you do not have an FTP proxy server, select No, and then click Next. For typical installations, the Storage Administration Portal Credentials dialog box opens. Proceed to step 15. For custom installations, the Installation Folder dialog box opens. Continue with step 12.. 12. Select an installation folder as follows, and then click Next.
14. Do one of the following: • If this is a new installation, select No, and then click Next. • If you are reinstalling the application and you want to use previously exported Storage Module for vCenter data, select Yes, and then click Next. Exported Server Module for vCenter data can be also be imported from the icvc folder. The Import Configuration Data dialog box opens. Click Next to import a file from the default location.
NOTE: To add additional vCenter servers, click the HP Insight Control Server Administrator for vCenter icon on your desktop or navigate to the vSphere/vCenter Home page, and then click the HP Insight Management Administration icon. The Install Summary dialog box displays a summary of the installation details. 17. Review the list, and then click Next. The wizard installs the product. Upon completion, the Install Complete dialog box opens and shows the installation directory.
Assigning the vCenter role Insight Control for vCenter uses role-based security access. Windows or domain users/groups can be assigned any of the vCenter roles.
7. • Specify the username, password, BMC IP address, and BMC MAC Address; and then click OK. From the HP Insight Management page: 1. Select a host. 2. From the host overview, click the setting icon and select Host Properties. 3. Select an iLO host. 4. Click the edit icon. 5. Change the credentials, and then click Submit. Upgrading Insight Control for vCenter NOTE: News feed events are not imported when upgrading Insight Control for vCenter from v7.1.2 to v7.2.
Removing the software If the Storage Module for vCenter is installed, when you remove Insight Control for vCenter, the Storage Module data is exported automatically to an export.si file that is saved in the installation directory. If the Server Module for vCenter is installed, the Server Module data is exported automatically to an icvc folder in the installation directory. To remove Insight Control for vCenter: 1.
3 Support and other resources This chapter describes the support available for Insight Control for vCenter.
HP authorized resellers For the name of the nearest HP authorized reseller, see the following sources: • In the United States, see the HP U.S. Partner Locator website: http://www.hp.com/service_locator • In other locations, see the Contact HP Worldwide website: http://www.hp.
4 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.
Glossary API Application Programming Interface. CIM Common Information Model. datastore A storage location for VM files in the VMware environment. DPM Distributed power management. ESX An enterprise-level virtualization product offered by VMware. ESXi The latest version of ESX. EVA Enterprise Virtual Array. FCP Fibre Channel Protocol. HP SIM HP Systems Insight Manager. iLO Integrated Lights-Out. J2EE Java 2 Platform, Enterprise Edition. LUN Logical unit number.
Index A ActiveX requirements, 10 administrator role assigning, 19 architecture, 4 C configuration, 9 core module, 4 D document related information, 23 documentation providing feedback on, 24 E exporting Storage Module for vCenter data, 21 H hardware requirements, 10 I iLO address setting up, 19 Insight Control for vCenter installing, 13 modules, 4 removing, 21 setting up, 18 upgrade, 20 installation, 9 Insight Control for vCenter, 13 L license, 9 license key, 9 license, Insight Control, 9 M modules I