nPartition Administrator's Guide

cell from the specified nPartition (-p#, where # is the partition number). From Partition
Manager select the nPartition, use the nPartitionModify nPartition action, and select the
Add/Remove Cells tab.
Also see Assigning (Adding) Cells to an nPartition” (page 179) and see “Unassigning
(Removing) Cells from an nPartition” (page 183).
Removing an nPartition
To remove (delete) an nPartition use the parremove -p# command to remove a specified
nPartition (-p#, where # is the partition number). From Partition Manager select the nPartition
and use the nPartitionDelete nPartition action.
Also see “Removing (Deleting) an nPartition” (page 176).
Renaming an nPartition
To rename an nPartition use the parmodify -p# -P name command to set the name for
a specified nPartition (-p#, where # is the partition number). From Partition Manager select
the nPartition, use the nPartitionModify nPartition action, and select the General tab.
On an HP 9000 server you also can use use the BCH Configuration menu PD NewName
command.
Also see “Renaming an nPartition” (page 187).
Setting Cell Attributes
To set attributes for a cell use the parmodify -p# -m#... command to modify cell
attributes for a specified nPartition (-p#, where # is the partition number).
From Partition Manager Version 1.0 select the nPartition, use the nPartitionModify
nPartition action, Change Cell Attributes tab, select the cell(s), and click Modify Cell(s).
From Partition Manager Version 2.0 select the nPartition, use the nPartitionModify
nPartition action, and use the Set Cell Options tab (to set the use-on-next-boot value) and
Configure Memory tab (to set the cell local memory value).
On an HP 9000 server you also can use the BCH Configuration menu CELLCONFIG command
to set use-on-next-boot values. On an HP Integrity server you also can use the EFI Shell
cellconfig command to set use-on-next-boot values.
Also see “Setting Cell Attributes” (page 190).
Setting Core Cell Choices
To set core cell choices for an nPartition use the parmodify -p# -r# -r#... command
to specify up to four core cell choices in priority order for a specified nPartition (-p#, where
# is the partition number).
From Partition Manager Version 1.0 select the nPartition, use the nPartitionModify
nPartition action, Core Cell Choices tab.
From Partition Manager Version 2.0 select the nPartition, use the nPartitionModify
nPartition action, Set Cell Options tab, and use the Core Cell Choice column to set
priorities.
On an HP 9000 server you can use the BCH Configuration menu COC command to set core
cell choices. On an HP Integrity server you can use the EFI Shell rootcell command to
set core cell choices.
Also see “Setting nPartition Core Cell Choices” (page 196).
Setting nPartition Boot Paths
On HP Integrity servers boot paths can be listed and configured only from the local nPartition.
32 Getting Started with nPartitions