System Specifications
Features
C-5
Features
Feature Description
Self-restart
Capability
Automatic Server Restart (ASR) that reboots incase
of embedded NOS hang
Environmental
Monitoring
Temperature, voltage, and fan-speed monitoring with
alarm capability
Self-Correcting
Memory
ECC capable with hardware error scrubbing; corrects
single bit errors, detects multiple bit errors
Hot-Swap
Subsystem
Supports 36GB and future low profile and half height
SCSI hard disks
Up to 10 hard disks
RAID Disk Array
Controller
Hardware RAID accelerator with 32MB of NVRAM
RAID5
Supports up to 10 hard disks with hot swap
Maximum RAID5 group of 8 drives
32MB NVRAM for cached write protection
Support for SMART capable disk drives
Automatic detection of hard disk failure with
automatic rebuild to global hot spare
Power Supply
Modules
Triple, redundant with hot swap
System can tolerate failure of one supply (two
required for minimum operation) (2+1 operation)
Audible alarm and network alarm for failure
Fans
2 Redundant fan assemblies with fan-speed
monitoring for system cooling
Fan hot swap supported
Boot Time Seconds from power on to file system available (after
proper shutdown, one 5 drive RAID5 partition, typical)
UPS Support
External Uninterruptible Power Supply (UPS)
monitoring through integrated serial port (DB9 male)
System shutdown initiated battery critical error
reported by UPS
Requires Sine-wave output
Support for the following APC Brand UPS:
APC Smart-UPS 700 Model APC SU700RMNET