Neoview Messages Manual (Volume 2) (R2.5)
13001
The option option is not supported, controlfile=cf
Cause Option name was not recognized.
Effect The Neoview Transporter Client stops processing the control file.
Recovery Check spelling, option name, and location of option in the control file. Correct and
resubmit the control file.
13003
Control file cf, PARSER ERROR=error
Cause Parser found incorrect syntax in provided control file.
Effect The client stops processing the control file.
Recovery Check spelling and area around the line number specified.
13005
The value of value for the option option is invalid, controlfile=cf
Cause Option value is not valid for the option it is paired with.
Effect The Neoview Transporter Client stops processing the control file.
Recovery Correct and resubmit the control file.
13006
The option option is not supported in the section section, controlfile=cf
Cause Option not valid for section in which it is used.
Effect The Neoview Transporter Client stops processing the control file.
Recovery Correct and resubmit the control file.
13010
Too few arguments, required arguments=arg_list
Cause Required arguments were not specified for the Control File Generator.
Effect Control File Generator terminates.
Recovery Ensure that all required arguments are specified and rerun the Control File
Generator.
13011
No JDBC source or targets in control file cf
Cause Control file must have at least one source or target.
Effect The Neoview Transporter Client stops processing the control file.
Recovery Make sure the control file has at least one source or target, and resubmit the control
file.
13012
DBT data was not created
Cause Control file could not be parsed.
Effect The Neoview Transporter Client stops processing the control file.
Recovery Correct the control file and resubmit.
17