Neoview Owner's Manual (R2.2)
Nonoperating Temperature, Humidity, and Altitude
• Temperature:
— Up to 72-hour storage: - 40× to 150× F (-40× to 66× C)
— Up to 6-month storage: -20× to 131× F (-29× to 55× C)
— Reasonable rate of change with noncondensing relative humidity during the transition
from warm to cold
• Relative humidity: 10 percent to 80 percent, noncondensing
• Altitude: 0 to 40,000 feet (0 to 12,192 meters)
Cooling Airflow Direction
Each enclosure includes its own forced-air cooling fans or blowers. Airflow for each enclosure
enters from the front of the modular cabinet and rack and exhausts at the rear.
Typical Acoustic Noise Emissions
• 70 dB(A) (sound pressure level at operator position)
Tested Electrostatic Immunity
• Contact discharge: 8 KV
• Air discharge: 20 KV
32 Installation Specifications for the Neoview Platform