Neoview Messages Manual (R2.2)
Cause Failed to receive the first data block from the gelserver on the Neoview platform.
Possibly:
• The gelserver process on the Neoview platform terminated before sending the first data
block. In this case, check the gelserver Neoview task instance log.
• Problems occurred in the network between the Neoview platform and the Linux system.
The error number value indicates the exact cause of error.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
Select on the socket failed. Error number = error.
error is the value of the errno variable returned by TCP/IP.
Cause The gelserver failed to perform the select operation on the data socket. The error
number value indicates the exact cause of error.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
Message could not be sent to peer gelserver. Error number = error.
error is the value of the errno variable returned by TCP/IP.
Cause The gelserver failed to send the “I am alive check” message to the peer gelserver
process running on the Neoview platform. The error number value indicates the exact cause
of error.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
No reply(2) from peer gelserver. Error number = error.
error is the value of the errno variable returned by TCP/IP.
Cause Failed to receive the second or subsequent data block from the gelserver on the
Neoview platform. Possibly:
• The gelserver process on the Neoview platform terminated before sending the first data
block. In this case, check the gelserver Neoview log.
• Problems occurred in the network between the Neoview platform and the Linux system.
The error number value indicates the exact cause of error.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
No reply(3) from peer gelserver. Error number == error.
error is the value of the errno variable returned by TCP/IP.
Cause Failed to receive the second or subsequent data block from the gelserver on the
Neoview platform. Possibly:
• The gelserver process on the Neoview platform performed an orderly shutdown of the
data receive socket.
• Problems occurred in the network between the Neoview platform and the Linux system.
The error number value indicates the exact cause of error.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
Message could not be sent to peer gelserver.
Cause Failed to send message to the gelserver on the Neoview platform. Possibly:
• The gelserver process on the Neoview platform has already terminated.
• Problems occurred in the network between the Neoview platform and the Linux system.
Recovery Contact the GMCSC for analysis of accompanying error and warning messages.
No reply from peer gelserver in response to message sent.
390 Neoview Loader