Neoview Messages Manual (R2.2)
SQL 11102
11102 MXUDR: Invalid UDR handle: string.
Cause The HP Neoview database UDR server received a request for a stored procedure
that is no longer present in the Neoview database UDR server context.
Effect The request message is rejected, and the HP Neoview SQL statement fails.
Recovery Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 11103
11103 MXUDR: Invalid routine handle: string.
Cause The HP Neoview database UDR server encountered an internal error. Either an HP
Neoview SQL language manager operation failed, or a Neoview database UDR server data
structure was determined to be invalid.
Effect The request message is rejected, and the Neoview SQL statement fails.
Recovery Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 11104
11104 MXUDR: CLI Error: text.
Cause The HP Neoview database UDR server encountered an unexpected error during an
internal Neoview database software operation. The message text includes the name of the
database software operation and the error code that was returned.
Effect At completion, the stored procedure might display unexpected results or side effects.
Recovery Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 11105
11105 MXUDR: Invalid Language Manager parameter mode. Parameter:
parameter-value.
Cause The HP Neoview database UDR server encountered an internal error. An unexpected
parameter mode value appeared in a request message.
Recovery Do not attempt recovery. HP support will perform recovery operations in response
to an automatically generated dial-out message about this condition.
SQL 11108
11108 MXUDR: Unable to allocate memory for object object-name.
object-name
is the name of the object.
Cause The HP Neoview database UDR server was not able to obtain enough memory to
allocate the named object.
Effect The request message is rejected, and the Neoview database software statement fails.
Recovery Stop and start the client process to restart a new Neoview database UDR server,
and retry the stored procedure call.
SQL 11110
11110 MXUDR: Unexpected error during message processing: string.
Cause The HP Neoview database UDR server encountered an internal error. Details appear
in the message text.
Effect The operation fails.
217