R2511-HP MSR Router Series Fundamentals Configuration Guide(V5)
32
Ste
p
Command
Remarks
6. Specify the number of data
bits in each character.
databits { 5 | 6 | 7 | 8 }
The default is 8.
The setting depends on the character
coding type. For example, you can
set it to 7 if standard ASCII
characters are to be sent, and set it
to 8 if extended ASCII characters
are to be sent.
7. Define the shortcut key for
starting a terminal session.
activation-key character
By default, you press Enter to start
the terminal session.
8. Define a shortcut key for
terminating tasks.
escape-key { default | character }
By default, pressing Ctrl+C
terminates a task.
9. Enable stop bits detection.
stopbit-error intolerance
By default, stop bits detection is
disabled.
10. Configure the flow control
mode.
flow-control { hardware | none |
software }
flow-control hardware
flow-control-type1 [ software
flow-control-type2 ]
flow-control software
flow-control-type1 [ hardware
flow-control-type2 ]
By default, the device does not
perform flow control.
11. Specify the terminal display
type.
terminal type { ansi | vt100 }
By default, the terminal display type
is ANSI.
The device supports two types of
terminal display: ANSI and VT100.
HP recommends that you set the
display type of both the device and
the terminal to VT100. If the device
and the client use different display
types (for example, HyperTerminal
or Telnet terminal) or both are set to
ANSI, when the total number of
characters of the currently edited
command line exceeds 80, an
anomaly such as cursor corruption
or abnormal display of the terminal
display might occur on the client.
12. Configure the user privilege
level for login users.
user privilege level level
By default, the default command
level is 3 for the console user
interface.
13. Set the maximum number of
lines to be displayed on a
screen.
screen-length screen-length
By default, a screen displays 24
lines at most.
A value of 0 disables pausing
between screens of output.
14. Set the size of command
history buffer.
history-command max-size value
By default, the buffer saves 10
history commands at most.