Fibre Channel Thermal Upgrade Kit
34
For rack mounted libraries, remove the library
from the rack. For table top libraries, remove
the outer cover. See the HP StorageWorks
MSL5000 and 6000 Series Tape Library User
Guide detailed instructions.
Remove the front cover and set aside.
Remove the right rear cover and discard, but
keep the screws.
56
Remove the cooling baffle plate and discard.
Disconnect the card cage cooling fan cable
from the card cage backplane (J11) and
remove the fan and finger guard from the
chassis. Access to the fan mounting fasteners
is through the area opened by removal of the
left side magazine.
Note: This fan will not be reused.
7
Using the
replacement
fan, thread
the power
cable with the Y connector through the access slot
at the top of the chassis toward the backplane.
Caution: Verify that the arrow at the top of
the fan points toward the front of the library.
This directs the airflow away from the card
cage and toward the front of the library.
Install the replacement card cage cooling fan and
finger guard with two screws.
8
Using the GUI, turn the library off.
Turn off the master power switch for
each power supply at the back of the
library, and then remove the AC power cord.
Note: This process automatically moves
the robot to the parked position.
Access
Slot