HP StorageWorks 2300 Family Modular Smart Array CLI reference guide (500912-002, July 2010)

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 139
Reason
0x8001: PHY disabled because of error-count interrupts.
0x8003: PHY disabled by PHY control page.
0x8004: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is
not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as
a broken connector.
0x8006: PHY disabled because drive slot is empty.
Example Show expander status for a single-enclosure system with an empty disk slot:
# show expander-status
Encl Ctlr Phy Type Status Elem Status Disabled Reason
-------------------------------------------------------------------------------
1 A 0 Drive Enabled-Healthy OK Enabled
1 A 1 Drive Disabled Disabled Disabled
...
1 A 23 Drive Disabled OK Disabled 0x8006
1 A 0 SC-1 Enabled-Healthy OK Enabled
1 A 1 SC-1 Enabled-Healthy OK Enabled
1 A 0 SC-0 Enabled-Healthy OK Enabled
...
1 A 3 SC-0 Enabled-Healthy OK Enabled
1 A 0 Egress Enabled-Healthy Non-critical Enabled
...
1 A 3 Egress Enabled-Healthy Non-critical Enabled
-------------------------------------------------------------------------------
Encl Ctlr Phy Type Status Elem Status Disabled Reason
-------------------------------------------------------------------------------
1 B 0 Drive Enabled-Healthy OK Enabled
1 B 1 Drive Enabled-Healthy OK Enabled
...
1 B 23 Drive Disabled OK Disabled 0x8006
1 B 0 SC-1 Enabled-Healthy OK Enabled
1 B 1 SC-1 Enabled-Healthy OK Enabled
1 B 0 SC-0 Enabled-Healthy OK Enabled
...
1 B 0 Egress Enabled-Healthy Non-critical Enabled
...
1 B 3 Egress Enabled-Healthy Non-critical Enabled
-------------------------------------------------------------------------------
See also clear expander-status
set expander-fault-isolation
set expander-phy