HP StorageWorks 2300 Family Modular Smart Array CLI reference guide (500912-002, July 2010)

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 129
show disk-parameters
Description Shows disk settings.
Syntax
show disk-parameters
Output SMART
Shows whether SMART is enabled or disabled for all disks, or is set to detect-only, which
specifies that each new disk inserted in the system retains its current SMART setting.
Drive Write Back Cache
Shows whether write-back cache for each disk in or added to the system will be enabled or disabled
or a rescan or controller restart. Don't Modify means that each disk's current setting will not be
modified.
Timeout Retry Maximum
Maximum number of times a timed-out I/O operation can be retried before the operation is failed.
Attempt Timeout
Number of seconds before an I/O operation is aborted and possibly retried.
Overall Timeout
Total time in seconds before an I/O operation is failed regardless of the Attempt Timeout and
Number of Retries settings.
Example Show disk settings:
# show disk-parameters
Disk Parameters
-------------
SMART: Enabled
Drive Write Back Cache: Disabled
Timeout Retry Maximum: 3
Attempt Timeout: 8
Overall Timeout: 105
See also set disk-parameters