HP StorageWorks 2300 Family Modular Smart Array CLI reference guide (500912-002, July 2010)

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 113
storage-size-base 2|10
Optional. Alias for base.
storage-size-precision #
Optional. Alias for precision.
storage-size-units auto|MB|GB|TB
Optional. Alias for units.
temperature-scale celsius|c|fahrenheit|f
Optional. Specifies to use the Celsius scale or Fahrenheit scale for temperature values.
timeout #
Optional. Sets the timeout value in seconds for the login session. Valid values are 30–9999, where
9999 means do not timeout. The default is 1800 seconds (30 minutes).
type standard|advanced|diagnostic
Optional. Specifies the user's level of technical expertise, to control access to functions in SMU.
standard: Enables access to standard administrative functions.
advanced: Enables access to standard and advanced functions.
diagnostic: Enables access to standard, advanced, and troubleshooting functions.
units auto|MB|GB|TB
Optional. Sets the unit for display of storage-space sizes. auto lets the system determine the proper
unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully
display a size, the system uses a smaller unit for that size.
user-name
Optional. Specifies the user profile to change. Names are case sensitive.
Example Change a user's type and interface access:
# set user jsmith type advanced interfaces wbi,cli
Success: User-Type set to advanced.
See also set password
show users