HP MSA Events Description Reference Guide (762785-001, March 2014)

62 Event descriptions
515
Info An FDE disk was repurposed by a user.
The disk was reset to its original factory state.
Recommended actions
No action is required.
516
Error An FDE disk has been placed in the unavailable state.
The related event message 518, which indicates that a disk operation failed, may provide additional
information.
Recommended actions
See the recommended action specified in the event message.
517
Info A disk that was formerly in the FDE unavailable state is no longer unavailable.
The disk has returned to normal operations.
Recommended actions
No action is required.
518
Error An FDE disk operation has failed.
This event provides detail about the operation that failed.
Recommended actions
The disk may need to be removed, imported, repurposed, or replaced.
521
Error An error occurred while accessing the midplane SEEPROM to store or fetch Full Disk Encryption keys.
The midplane’s memory is used to store the FDE lock key.
Recommended actions
The midplane may need to be replaced if the error persists.