HP MSA 2040 CLI Reference Guide

468 XML API basetype properties
sensors
This basetype is used by show sensor-status.
Table 71 sensors properties
Name Type Description
durable-id string Sensor ID. For example: sensor_temp_ctrl_
controller-ID.sensor-
number
and sensor_volt_ctrl_
controller-ID.sensor-number
.
enclosure-id uint32 Enclosure ID.
sensor-name string Sensor name and location.
value string For a sensor, its value.
For overall unit status, one of the status values below.
status string Ok: The sensor is present and detects no error condition.
Warning: The sensor detected a non-critical error condition. Temperature,
voltage, or current is between the warning and critical thresholds.
Error: The sensor detected a critical error condition. Temperature, voltage,
or current exceeds the critical threshold.
Unavailable: The sensor is present with no known errors, but has not
been turned on or set into operation because it is initializing. This typically
occurs during controller startup.
Unrecoverable: The enclosure management processor (EMP) cannot
communicate with the sensor.
Unknown: The sensor is present but status is not available.
Not Installed: The sensor is not present.
Unsupported: Status detection is not implemented.
status-numeric uint32 Numeric equivalents for status values.
0: Unsupported
1: OK
2: Error
3: Warning
4: Unrecoverable
5: Not Installed
6: Unknown
7: Unavailable
sensor-location uint32 Sensor location in a controller enclosure.
1: Unknown
2: Overall unit status
5: Power supply unit
7: Enclosure
8: On board
sensor-type uint32 2: Overall unit status
3: Temperature
6: Capacitor charge
9: Voltage