HP MSA 2040 CLI Reference Guide

redundancy 445
redundancy
This basetype is used by show redundancy-mode.
Table 55 redundancy properties
Name Type Description
redundancy-mode string The system’s operating mode, also called the cache redundancy mode.
Active-Active ULP: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault tolerance.
Single Controller: The enclosure contains a single controller.
Failed Over: Operation has failed over to one controller because its
partner is not operational. The system has lost redundancy.
Down: Both controllers are not operational.
redundancy-
mode-numeric
uint32 Numeric equivalents for redundancy-mode values.
2: Active-Active ULP
3: Single Controller
4: Failed Over
5: Down
redundancy-
status
string Redundant: Both controllers are operational.
Operational but not redundant: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
Down: This controller is not operational.
Unknown: Status information is not available.
redundancy-
status-numeric
uint32 Numeric equivalents for redundancy-status values.
1: Redundant
3: Operational but not redundant
4: Down
5: Unknown
controller-a-
status
string Operational: The controller is operational.
Down: The controller is installed but not operational.
Not Installed: The controller is not installed.
controller-a-
status-numeric
uint32 Numeric equivalents for controller-a-status values.
0: Operational
1: Down
2: Not Installed
controller-a-
serial-number
string Controller module serial number
Not Available: The controller is down or not installed.
controller-b-
status
string Operational: The controller is operational.
Down: The controller is installed but not operational.
Not Installed: The controller is not installed.
controller-b-
status-numeric
uint32 Numeric equivalents for controller-b-status values.
0: Operational
1: Down
2: Not Installed
controller-b-
serial-number
string Controller module serial number
Not Available: The controller is down or not installed.