HP MSA 2040 CLI Reference Guide
412 XML API basetype properties
midplane-type string Enclosure midplane type.
• 2U24-6Gv2: Midplane for 2U, reduced-depth, 24-disk enclosure with
6-Gbit/s maximum data rate to disks (HP MSA 2040 SFF chassis)
• 2U24-6G: Midplane for 2U, 24-disk enclosure with 6-Gbit/s maximum data
rate to disks (HP P2000 SFF chassis)
• 2U12-6Gv2: Midplane for 2U, reduced-depth, 12-disk enclosure with
6-Gbit/s maximum data rate to disks (HP MSA 2040 LFF chassis)
• 2U12-6G: Midplane for 2U, 12-disk enclosure with 6-Gbit/s maximum data
rate to disks (HP P2000 LFF chassis)
• N/A: Other type of midplane
midplane-type-
numeric
uint32 Numeric equivalents for midplane-type values.
• 0: 2U12-3G
• 1: 2U24-3G
• 2: 2U12-6G
• 3: 2U24-6G
• 5, 9, 13: 2U24-6Gv2
• 6, 10: 2U12-6Gv2
enclosure-power string Enclosure power in watts.
pcie2-capable string • False: Enclosure is not capable of using PCI Express version 2.
• True: Enclosure is capable of using PCI Express version 2.
pcie2-capable-
numeric
uint32 Numeric equivalents for pcie2-capable values.
• 0: False
• 1: True
health string • OK
• Degraded
• Fault
• Unknown
health-numeric uint32 Numeric equivalents for health values.
• 0: OK
• 1: Degraded
• 2: Fault
• 3: Unknown
health-reason string If Health is not OK, the reason for the health state.
health-
recommendation
string If Health is not OK, the recommended actions to take to resolve the health issue.
unhealthy-
component
Embedded; see unhealthy-component.
controllers Embedded; see controllers, io-modules.
power-supplies Embedded; see power-supplies.
fan-details Embedded; see fan.
Table 30 enclosures properties (continued)
Name Type Description