HP MSA 2040 CLI Reference Guide

388 XML API basetype properties
redundancy-
status
string Redundant: Both controllers are operational.
Operational but not redundant: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
Down: This controller is not operational.
Unknown: Status information is not available.
redundancy-
status-numeric
uint32 Numeric equivalents for redundancy-status values.
0: Operational but not redundant
3: Redundant
4: Down
5: Unknown
unhealthy-
component
Embedded; see unhealthy-component.
ip-address Embedded; see network-parameters.
port-details Embedded; see port.
enclosure-id Embedded; see expander-ports.
compact-flash Embedded; see compact-flash.
Table 19 controllers properties (continued)
Name Type Description