HP MSA 2040 CLI Reference Guide
show expander-status 241
Disabled
• Enabled: PHY is enabled.
• Disabled: PHY is disabled.
Reason
• Blank if Elem Status is OK.
• Error count interrupts: PHY disabled because of error-count interrupts.
• Phy control: PHY disabled by a SES control page as a result of action by a Storage
Controller or user.
• Not ready: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O
module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem
exists such as a broken connector.
• Drive removed: PHY disabled because drive slot is empty.
• Unused - disabled by default: PHY is disabled by default because it is not used.
• Excessive Phy changes: PHY is disabled because of excessive PHY change counts.
Example Show expander status for a 2U24 system:
# show expander-status
Encl Ctlr Phy Type Status Elem Status Disabled
Reason
-----------------------------------------------------------------------------
1 A 0 Drive Enabled - Healthy OK Enabled
1 A 1 Drive Disabled OK Disabled
Drive removed
...
-----------------------------------------------------------------------------
Encl Ctlr Phy Type Status Elem Status Disabled
Reason
-----------------------------------------------------------------------------
1 B 0 Drive Enabled - Healthy OK Enabled
1 B 1 Drive Disabled OK Disabled
Drive removed
...
-----------------------------------------------------------------------------
Success: Command completed successfully. (2013-07-31 15:02:13)
Basetypes • sas-status-controller-a
• status
See also • clear expander-status
• set expander-fault-isolation
• set expander-phy