set controller-date 147
set controller-date
Description Sets the date and time parameters for the system. You can set the date and time manually or
configure the system to communicate with a Network Time Protocol (NTP) server. Alternatively, you
can configure NTP by using the set ntp-parameters command.
NOTE: If you specify valid NTP parameters and manual date/time parameters in the same
command, the NTP parameters will take precedence. If the NTP server cannot be contacted, the date
and time will not be changed and no error message will be displayed.If you specify the timestamp
parameter and other manual date/time parameters in the same command, the timestamp
parameter will take precedence.
Syntax To set the date and time manually:
set controller-date
jan|feb|mar|apr|may|jun|jul|aug|sep|oct|nov|dec
day
hh
:
mm
:
ss
year
To set the date and time manually by specifying a timestamp:
set controller-date
timestamp
timestamp
timezone +|-
hh
[:
mm
]
To configure use of NTP:
set controller-date
ntp enabled|disabled|on|off
ntpaddress
IP-address
timezone +|-
hh
[:
mm
]
Parameters jan|feb|mar|apr|may|jun|jul|aug|sep|oct|nov|dec
The month.
day
The day number (1–31).
hh
:
mm
:
ss
The hour (0–23), the minutes (0–59), and the seconds (0–59).
year
The year as a four-digit number.
ntp enabled|disabled|on|off
Enables or disables use of NTP. When NTP is enabled and the specified NTP server is available,
each controller’s time is synchronized with the server.
ntpaddress
IP-address
The network address of an available NTP server.
timezone +|-
hh
[:
mm
]
The system’s time zone as an offset in hours (-12 through +14) and optionally minutes (00–59) from
Coordinated Universal Time (UTC). To specify a positive offset, the '+' is optional; to specify a
negative offset, the '-' is required. The hour value can have one or two digits and can omit a leading
zero. If the minutes value is specified it must have two digits; if it is omitted, the minutes value is set to
00.