HP MSA Events Description Reference Guide (762785-001, March 2014)

Event descriptions 39
269
Info. A partner firmware update operation has started. This operation is used to copy firmware from one
controller to the other to bring both controllers up to the same version of firmware.
Recommended actions
No action is required.
270
Warning Either there was a problem reading or writing the persistent IP data from the FRU ID SEEPROM, or invalid
data were read from the FRU ID SEEPROM.
Recommended actions
Check the IP settings (including iSCSI host-port IP settings for an iSCSI system), and update them if they
are incorrect.
271
Info. The storage system could not get a valid serial number from the controller’s FRU ID SEEPROM, either
because it couldn’t read the FRU ID data, or because the data in it are not valid or have not been
programmed. Therefore, the MAC address is derived by using the controller’s serial number from flash.
This event is only logged one time during bootup.
Recommended actions
No action is required.
272
Info. Expansion of the indicated snap pool has started.
Recommended actions
No action is required.
273
Info. PHY fault isolation has been enabled or disabled by a user for the indicated enclosure and controller
module.
Recommended actions
No action is required.