HP MSA 2040 CLI Reference Guide

412 XML API basetype properties
midplane-type string Enclosure midplane type.
2U24-6Gv2: Midplane for 2U, reduced-depth, 24-disk enclosure with
6-Gbit/s maximum data rate to disks (HP MSA 2040 SFF chassis)
2U24-6G: Midplane for 2U, 24-disk enclosure with 6-Gbit/s maximum data
rate to disks (HP P2000 SFF chassis)
2U12-6Gv2: Midplane for 2U, reduced-depth, 12-disk enclosure with
6-Gbit/s maximum data rate to disks (HP MSA 2040 LFF chassis)
2U12-6G: Midplane for 2U, 12-disk enclosure with 6-Gbit/s maximum data
rate to disks (HP P2000 LFF chassis)
N/A: Other type of midplane
midplane-type-
numeric
uint32 Numeric equivalents for midplane-type values.
0: 2U12-3G
1: 2U24-3G
2: 2U12-6G
3: 2U24-6G
5, 9, 13: 2U24-6Gv2
6, 10: 2U12-6Gv2
enclosure-power string Enclosure power in watts.
pcie2-capable string False: Enclosure is not capable of using PCI Express version 2.
True: Enclosure is capable of using PCI Express version 2.
pcie2-capable-
numeric
uint32 Numeric equivalents for pcie2-capable values.
0: False
1: True
health string OK
Degraded
Fault
Unknown
health-numeric uint32 Numeric equivalents for health values.
0: OK
1: Degraded
2: Fault
3: Unknown
health-reason string If Health is not OK, the reason for the health state.
health-
recommendation
string If Health is not OK, the recommended actions to take to resolve the health issue.
unhealthy-
component
Embedded; see unhealthy-component.
controllers Embedded; see controllers, io-modules.
power-supplies Embedded; see power-supplies.
fan-details Embedded; see fan.
Table 30 enclosures properties (continued)
Name Type Description