HP MSA 2040 CLI Reference Guide

show cache-parameters 209
Example Show the cache parameters for the system and for volume V1:
# show cache-parameters V1
System Cache Parameters
-----------------------
Operation Mode: Active-Active ULP
Controller A Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
CompactFlash Health: OK
Cache Flush: Enabled
Controller B Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
CompactFlash Health: OK
Cache Flush: Enabled
Volume Cache Parameters
-----------------------
Serial Number:
SN
Name: V1
Cache Write Policy: write-back
Cache Optimization: standard
Read Ahead Size: Adaptive
Success: Command completed successfully. (2012-12-14 14:31:19)
Basetypes cache-settings
cache-parameter
status
See also set cache-parameters
show volumes