9. Present the LUN:
a. In the left pane, expand the tree, and then under the Storage node, click LUNs.
b. In the right pane, select the LUN Management tab.
c. On the LUN Management page, right-click the volume that you want to present to the
data migration appliance, and click Properties.
d. Complete the LUN Volume xx Properties page (see Figure 51 (page 61)):
i. Select the Initiators tab.
ii. Under Known initiator hosts, select the initiator group name that you specified in
Step 5.
iii. Click the right-arrow button to move the selected initiator group to the Hosts to connect
box on the right.
iv. Click Apply.
Figure 51 Selecting Hosts to Connect
Assigning LUNs from a NetApp Cluster-Mode array
NetAppStorage vendor
Data ONTAP 8.0 Cluster-ModeArray model
NetApp Data ONTAP Element ManagerLUN assignment tool
To assign LUNs:
1. Perform zoning:
a. Connect the FC ports of the data migration appliance to a switch where the storage
controller ports are also logged.
b. Use switch management tools to create a zone, DM_Host_Netapp.
c. In the new zone, add the WWPN of the data migration appliance FC ports and storage
controller ports.
d. Save the zoning information and activate the new zoning configuration.
2. In a Web browser, open the NetApp Data ONTAP Element Manager tool by entering the
array management IP address.
Assigning LUNs from NetApp Systems 61