HP MPX200 Data Migration Planning Guide
Figure 26 Adding DM-Host to Storage Group
NOTE: Before assigning LUNs, you must register as a single host entity all router ports that
will access the same LUNs as a single host entity. If you add a new router port to an existing
host entity, that port will not appear as a new path for the assigned LUNs in the router’s show
luninfo command output.
8. Add LUNs to the DM-Host storage group entity (see Figure 27 (page 43)):
a. Under the Storage Groups tree, right-click DM-Host.
b. Click Select LUNs to view a list of available LUNs.
c. In the DM-Host: Storage Group Properties dialog box, select the LUNs tab.
d. On the LUNs page, select All in the Show LUNs list to view all LUNs that have been
assigned to the host and will be part of the data migration jobs.
e. Under Available LUNs, select the check box next to each LUN to be assigned for data
migration jobs (as determined during the planning phase of the data migration activity).
42 Assigning LUNs to the MPX200 for data migration