HP MPX200 Data Migration Planning Guide

Table 13 Example A: pre-migration FC zoning information (continued)
Server, MPX200, storage nameZone members (WWPNs)FC Zone name
FC Switch and IP
address
iPortal: P221-00-00-C0-DD-C0-55-58
Sales: P221-00-00-C0-DD-C0-60-67
SRC-Array-ABC: P250-06-01-61-41-E0-18-94
SRC-Array-ABC: P450-06-01-63-41-E0-18-94
Table 14 (page 20) shows new FC zone information to configure MPX200 for data migration and
to migrate the data. The MPX200 FC ports are configured with source and destination arrays.
Table 14 Example B: pre-migration FC zoning information
Server, MPX200, storage nameZone members (WWPNs)FC Zone name
FC Switch and IP
address
MPX200, FC121-00-00-C0-DD-C0-88-81Zone-A-DMFC-SW-1 10.5.3.1
SRC-Array-ABC: P150-06-01-60-41-E0-18-94
SRC-Array-ABC: P350-06-01-62-41-E0-18-94
DEST-Array-XYZ: P150-00-1F-E1-50-06-22-A1
DEST-Array-XYZ: P350-00-1F-E1-50-06-22-A2
MPX200: FC221-00-00-C0-DD-C0-88-82Zone-B-DMFC-SW-1 10.5.3.2
SRC-Array-ABC: P250-06-01-61-41-E0-18-94
SRC-Array-ABC: P450-06-01-63-41-E0-18-94
DEST-Array-XYZ: P250-00-1F-E1-50-06-22-A8
DEST-Array-XYZ: P450-00-1F-E1-50-06-22-A9
Table 15 (page 20) shows an example of post-migration FC zoning information.
Table 15 Example C: post-migration FC zoning information
Server, MPX200, storage nameZone members (WWPNs)FC Zone name
FC Switch and IP
address
HR-Dept: P121-00-00-C0-DD-C0-8A-D7Zone-AFC-SW-1/10.5.3.1
iPortal: P121-00-00-C0-DD-C0-55-57
Sales: P121-00-00-C0-DD-C0-60-66
DEST-Array-XYZ: P150-00-1F-E1-50-06-22-A1
DEST-Array-XYZ: P350-00-1F-E1-50-06-22-A2
HR-Dept: P221-00-00-C0-DD-C0-88-82Zone-BFC-SW-1 10.5.3.2
iPortal: P250-06-01-61-41-E0-18-94
Sales: P250-06-01-63-41-E0-18-94
DEST-Array-XYZ: P250-00-1F-E1-50-06-22-A8
DEST-Array-XYZ: P450-00-1F-E1-50-06-22-A9
20 Checklist examples