HP Matrix Operating Environment 7.1 Release Notes
Patch required to register HP Integrity VM hosts running Integrity VM 4.1 or higher and 11.31
HA-OE or DC-OE
The Insight managed system setup wizard fails to register HP Integrity VM hosts running Integrity
VM 4.1 or higher and either the 11.31 High Availability Operating Environment (HA-OE) or the
11.31 Data Center Operating Environment (DC-OE).
Suggested action
Apply the patch PHSS_40784 to the HP-UX 11i v3 Integrity VM host. The patch is needed on
systems where Serviceguard is installed, but the systems are not actively in a Serviceguard cluster.
Serviceguard is included with the HP-UX 11i v3 HA-OE and DC-OE.
You can download this patch from http://www.hp.com/go/hpsc. Log on with your HP passport,
and select Patch management from the Download options menu. Type PHSS_40784 in the search
box.
HP Integrated Lights-Out 3 (iLO3) support
HP Integrated Lights-Out 3 (iLO3) is supported in the current release of Insight managed system
setup wizard. However, iLO3 for ProLiant requires firmware version 1.05 or higher.
Suggested action
Update iLO3 ProLiant firmware to version 1.05 or higher.
HP Integrity rx2620 is not supported
In this release, using the Insight managed system setup wizard to configure an HP Integrity rx2620
server is not supported.
Suggested action
Manually configure HP Integrity rx2620 servers.
Instant Capacity Manager
Limitations
Commands executed under privilege elevation may cause Instant Capacity Manager to monitor
but not control managed nodes
Some HP-UX security settings cause output to be generated every time a user is logged in. This can
occur, for example when sudo is used in Systems Insight Manager privilege elevation mode to
execute commands on HP-UX managed nodes, which can generate apparently extraneous output
to stderr. This output may be interpreted by some Instant Capacity (iCAP) Manager functions
executed under privilege elevation as error output from those commands.
When this apparent error output occurs, the affected iCAP Manager functions fail. In this scenario,
iCAP Manager can be used only to monitor, and not control, managed nodes configured in this
way.
NOTE: HP Integrity Superdome 2 systems obtain monitoring data by executing commands using
sudo. Monitoring data may not be available in this scenario.
Suggested action
Configure HP-UX managed nodes so that no extraneous output is generated when the sudo
command is executed.
For more information, see the following HP-UX documentation:
• HP-UX 11i Security Containment Administrator’s Guide
• HP-UX System Administrator's Guide: Configuration Management (HP-UX 11i v3)
Instant Capacity Manager 29